High-voltage battery racks for integration with separately specified PCS and controls.
- Catalogue energy class
- 64 kWh / 192 kWh
- Nominal energy
- To confirm / 192.9216 kWh
Plan cabinet integration around the business load profile, equipment location, system interfaces and local installation requirements.
Discuss this system
Concept illustration · not a model specification
Concept visualization · confirm actual model with our teamStart with the business demand profile and installation location. Review the cabinet, power conversion, controls and site responsibilities together.
Agree the module arrangement, identification and supplied configuration.
Review your brief →01 Measured demand profile or representative load schedule
02 Proposed equipment location and access information
03 Engineering responsibilities and document requirements
Review against the selected model and project requirements.
Review against the selected model and project requirements.
Review against the selected model and project requirements.
Review against the selected model and project requirements.
High-voltage battery racks for integration with separately specified PCS and controls.
Size battery energy separately from AC power; specify PCS and operating modes for the project.
Size battery energy separately from AC power; specify PCS and operating modes for the project.
Product families retained from the original company brochure.
Select by power and required duration; define the complete configuration in the technical offer.
Integrated battery, PCS and controls with project-specific parallel configurations.
Air-cooled AC storage system for commercial and industrial sites.
Supports scheduled charge/discharge, EMS export control and remote operation.
Direct PV integration with battery storage, power conversion and system controls.
Explore the pretty storage product range. Model references identify the technical configurations; availability, branding and OEM / ODM scope are confirmed in the offer.
Complete product tables, including the source’s qualifications and missing values.
The series and source pages are included in your brief. You can shortlist up to 15 references.
Review your project brief →Catalogue pp. 15 · Original model references retained. Confirm the configuration in the written technical offer.
| Specification | LNFZ-R-64KWh | LNFZ-R-192KWh |
|---|---|---|
| Catalogue energy class | 64 kWh | 192 kWh |
| Nominal energy | To confirm | 192.9216 kWh |
| Nominal voltage | To confirm | 614.4 V |
| Capacity | 314 Ah | |
| Standard charge / discharge | 150 / 150 A | |
| Operating voltage | 172.8–233.6 V | 518.4–700.8 V |
| Charge cut-off | 233.6 V | 700.8 V |
| Discharge cut-off | 172.8 V | 518.4 V |
| Weight | 480 kg | 1,500 kg |
| Charge / discharge temperature | 0–55°C / −10–60°C | |
| Storage humidity | 5–75% RH | |
| Source cycle figure | ≥8,000; test conditions to confirm | |
The 64 kWh source voltage and energy conflict. Confirm mechanical dimensions and final configuration.
“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.
The series and source pages are included in your brief. You can shortlist up to 15 references.
Review your project brief →Catalogue pp. 16–17 · Original model references retained. Confirm the configuration in the written technical offer.
| Specification | LNFZ-C-64KWh | LNFZ-C-80KWh | LNFZ-C-96KWh |
|---|---|---|---|
| Nominal energy (kWh) | 64.181 | 80.384 | 96.4608 |
| Nominal voltage (V) | To confirm | 256 | 307.2 |
| Charge cut-off (V) | 233.6 | 292 | 350.4 |
| Operating voltage (V) | 172.8-233.6 | 216-292 | 259.2-350.4 |
| Discharge cut-off (V) | 172.8 | 216 | 259.2 |
| Weight (kg) | 580 | 680 | 780 |
| Rated capacity | 314 Ah | ||
| Standard charge / discharge | 150 / 150 A | ||
| Chemistry | LFP | ||
| Charge / discharge temperature | 0–55°C / −10–60°C | ||
| Storage humidity | 5–75% RH | ||
| Dimensions / final configuration | Confirm model drawing | ||
Source data for 64 and 257 kWh models contain conflicts; other series are not used as substitutes.
| Specification | LNFZ-C-112KWh | LNFZ-C-128KWh | LNFZ-C-145KWh |
|---|---|---|---|
| Nominal energy (kWh) | 112.5376 | 128.6144 | 144.6912 |
| Nominal voltage (V) | 358.4 | 409.6 | 460.8 |
| Charge cut-off (V) | 408.8 | 467.2 | 525.6 |
| Operating voltage (V) | 302.4-408.8 | 345.6-467.2 | 388.8-525.6 |
| Discharge cut-off (V) | 302.4 | 345.6 | 388.8 |
| Weight (kg) | 880 | 1,180 | 1,280 |
| Rated capacity | 314 Ah | ||
| Standard charge / discharge | 150 / 150 A | ||
| Chemistry | LFP | ||
| Charge / discharge temperature | 0–55°C / −10–60°C | ||
| Storage humidity | 5–75% RH | ||
| Dimensions / final configuration | Confirm model drawing | ||
Source data for 64 and 257 kWh models contain conflicts; other series are not used as substitutes.
“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.
The series and source pages are included in your brief. You can shortlist up to 15 references.
Review your project brief →Catalogue pp. 18–19 · Original model references retained. Confirm the configuration in the written technical offer.
| Specification | LNFZ-C-161KWh | LNFZ-C-177KWh | LNFZ-C-193KWh | LNFZ-C-209KWh |
|---|---|---|---|---|
| Nominal energy (kWh) | 160.768 | 176.8448 | 192.9216 | 208.9984 |
| Capacity (Ah) | 314 | 314 | 314 | 314 |
| Nominal voltage (V) | 512 | 563.2 | 614.4 | 665.6 |
| Charge cut-off (V) | 584 | 642.4 | 700.8 | 759.2 |
| Operating voltage (V) | 432-584 | 475.2-642.4 | 518.4-700.8 | 561.6-759.2 |
| Discharge cut-off (V) | 432 | 475.2 | 518.4 | 561.6 |
| Standard charge / discharge (A) | 150 | 150 | 150 | 150 |
| Weight (kg) | 1,380 | 1,480 | 1,580 | 1,680 |
| Chemistry | LFP | |||
| Charge / discharge temperature | 0–55°C / −10–60°C | |||
| Storage humidity | 5–75% RH | |||
| Dimensions / final configuration | Confirm model drawing | |||
| Enclosure rating (series) | IP55 | |||
| Maintenance (series) | OTA; confirm controller configuration | |||
Source data for 64 and 257 kWh models contain conflicts; other series are not used as substitutes.
| Specification | LNFZ-C-225KWh | LNFZ-C-241KWh | LNFZ-C-257KWh |
|---|---|---|---|
| Nominal energy (kWh) | 225.0752 | 241.152 | To confirm |
| Capacity (Ah) | 314 | 314 | 628 |
| Nominal voltage (V) | 716.8 | 768 | To confirm |
| Charge cut-off (V) | 821.3 | 879.7 | 467.2 |
| Operating voltage (V) | 607.5-821.3 | 650.7-879.7 | 345.6-467.2 |
| Discharge cut-off (V) | 607.5 | 650.7 | 345.6 |
| Standard charge / discharge (A) | 150 | 150 | 200 |
| Weight (kg) | 1,780 | 1,880 | 2,000 |
| Chemistry | LFP | ||
| Charge / discharge temperature | 0–55°C / −10–60°C | ||
| Storage humidity | 5–75% RH | ||
| Dimensions / final configuration | Confirm model drawing | ||
| Enclosure rating (series) | IP55 | ||
| Maintenance (series) | OTA; confirm controller configuration | ||
Source data for 64 and 257 kWh models contain conflicts; other series are not used as substitutes.
“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.
The series and source pages are included in your brief. You can shortlist up to 15 references.
Review your project brief →Catalogue pp. 20 · Original model references retained. Confirm the configuration in the written technical offer.
| Specification | 71 kWh DC | 50 kW / 135 kWh |
|---|---|---|
| Architecture | DC battery cabinet | PV-storage cabinet |
| Storage energy | 71 kWh | 135 kWh |
| Listed power | Not supplied | 50 kW |
| Cooling | Air-conditioned air cooling | |
| Voltage / dimensions / interfaces | To confirm | |
Overview data only; request the exact model datasheet.
“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.
The series and source pages are included in your brief. You can shortlist up to 15 references.
Review your project brief →Catalogue pp. 21 · Original model references retained. Confirm the configuration in the written technical offer.
| Specification | 100 kW / 215 kWh | 125 kW / 261 kWh |
|---|---|---|
| Storage energy | 215 kWh | 261 kWh |
| Rated power | 100 kW | 125 kW |
| Architecture | AC/DC integrated | |
| Cooling | Liquid cooling | |
| Voltage / dimensions / interfaces | To confirm | |
Listed separately from HLY models; equal energy ratings do not imply identical products.
“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.
The series and source pages are included in your brief. You can shortlist up to 15 references.
Review your project brief →Catalogue pp. 22–24 · Original model references retained. Confirm the configuration in the written technical offer.
| Specification | HLY-ELS24001Y215K | HLY-ELS26001Y232K | HLY-ELS24001Y241K | HLY-ELS26001Y261K |
|---|---|---|---|---|
| Battery energy | 215 kWh | 232 kWh | 241 kWh | 261 kWh |
| Rated power | 100 kW | 125 kW | 125 kW | 125 kW |
| Cell specification | LFP 3.2 V / 280 Ah | LFP 3.2 V / 280 Ah | LFP 3.2 V / 314 Ah | LFP 3.2 V / 314 Ah |
| Nominal DC voltage | 768 V | 832 V | 768 V | 832 V |
| DC voltage range | 648–876 V | 702–949 V | 648–876 V | 702–949 V |
| Grid voltage | 400 V | |||
| Rated AC current | 144 A | 180 A | 180 A | 180 A |
| THDi at rated power | <2.5% | <3% | <3% | <3% |
| Grid frequency | 50 / 60 Hz | |||
| AC overload | 1.1× continuous; 1.2× 1 min | |||
Verify certification by exact model, certificate and supplying entity; supplier certificates do not automatically certify the offered configuration.
| Specification | HLY-ELS24001Y215K | HLY-ELS26001Y232K | HLY-ELS24001Y241K | HLY-ELS26001Y261K |
|---|---|---|---|---|
| Rated power factor | >0.99 | |||
| Adjustable power factor | −1 to +1 | |||
| Battery thermal management | Liquid cooling/heating, 50% glycol-water | |||
| AC-side cooling | Air cooling | |||
| Fire suppression | Aerosol | |||
| Protection / corrosion class | IP55 / C3; C4, C5 optional | |||
| Operating / storage temperature | −20–55°C / −20–45°C | |||
| Storage condition | SOC 30–50%, <6 months | |||
| Humidity | 0–95% RH, non-condensing | |||
| Installation | Outdoor | |||
| Altitude | ≤2,000 m; derate above | |||
| Communication | Ethernet / RS485 | |||
Verify certification by exact model, certificate and supplying entity; supplier certificates do not automatically certify the offered configuration.
| Specification | HLY-ELS24001Y215K | HLY-ELS26001Y232K | HLY-ELS24001Y241K | HLY-ELS26001Y261K |
|---|---|---|---|---|
| Protocols | Modbus TCP / RTU / MQTT | |||
| Dimensions W×D×H | 1,000 × 1,350 × 2,390 mm | |||
| Weight | 2,500±150 kg | 2,600±150 kg | 2,500±150 kg | 2,600±150 kg |
| Source cycle figure | ≥8,000 @ 0.5C, 25±2°C, EOL ≥70% | |||
| Source-listed standards / documents* | None listed | IEC62619 / IEC61000 / RoHS / UN38.3 / MSDS | GB/T36276 / IEC62619 / IEC63056 / IEC62477 / IEC61000 / RoHS / UN38.3 / MSDS | GB/T36276 / IEC62619 / IEC63056 / IEC62477 / IEC61000 / RoHS / UN38.3 / MSDS |
Verify certification by exact model, certificate and supplying entity; supplier certificates do not automatically certify the offered configuration.
“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.
The series and source pages are included in your brief. You can shortlist up to 15 references.
Review your project brief →Catalogue pp. 25–26 · Original model references retained. Confirm the configuration in the written technical offer.
| Specification | HLY-ELS11201F 112K |
|---|---|
| Battery energy | 112 kWh |
| Rated AC power | 50 kW |
| Cell specification | LFP / 3.2 V / 314 Ah |
| Module / system configuration | 1P16S / 1P112S |
| Battery voltage range | 280–408.8 V |
| Maximum DC current | 150 A |
| AC voltage | 400 / 230 V |
| Rated AC current | 73 A |
| Frequency | 50 Hz (47–52 Hz) / 60 Hz (57–62 Hz) |
| Harmonics (>30% load) | <3% |
The similarly named 112K PV-storage model has different PV, voltage and dimension data.
| Specification | HLY-ELS11201F 112K |
|---|---|
| Dimensions | 1,350 × 1,295 × 2,377 mm |
| Communication | CAN / Ethernet |
| Protection | IP54 |
| Fire suppression | Aerosol + multi-sensor detector |
| Operating temperature | −20–50°C |
| Humidity | 0–95%, non-condensing |
| Altitude | ≤2,000 m; derate above |
The similarly named 112K PV-storage model has different PV, voltage and dimension data.
“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.
The series and source pages are included in your brief. You can shortlist up to 15 references.
Review your project brief →Catalogue pp. 27–28 · Original model references retained. Confirm the configuration in the written technical offer.
| Specification | HLY-ELS24001F 241K |
|---|---|
| Installed energy | 241.152 kWh |
| Rated AC power | 100 kW |
| DC voltage range | 600–876 V |
| Maximum DC current | 150 A |
| Maximum DC power | 100 kW |
| AC voltage / wiring | 380 V / 3/N/PE |
| Grid frequency | 50±2.5 Hz |
| Grid voltage tolerance | −10% / +15% |
| THDi at full load | ≤3% |
| Power factor | −1 to +1 |
Figures apply to the listed models. Options, operating conditions and supply scope are defined in the technical agreement.
| Specification | HLY-ELS24001F 241K |
|---|---|
| Energy efficiency at rated condition | ≥88% |
| Operating temperature | −20–50°C |
| Humidity | ≤95%, non-condensing |
| Noise | ≤65 dB |
| Cooling | Smart air cooling |
| Fire suppression | Automatic perfluorohexanone system |
| Protection / altitude | IP55 / ≤2,000 m; derate above |
| Weight | 3.2 t |
| Communication interfaces | 4G / LAN / EtherCAT / RS485 |
| Protocols | Modbus TCP / IEC104 |
| Dimensions W×D×H | 1,600 × 1,100 × 2,360 mm |
Figures apply to the listed models. Options, operating conditions and supply scope are defined in the technical agreement.
“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.
The series and source pages are included in your brief. You can shortlist up to 15 references.
Review your project brief →Catalogue pp. 29–31 · Original model references retained. Confirm the configuration in the written technical offer.
| Specification | HLY-ELS06401F64K | HLY-ELS11201F112K | HLY-ELS15601Y157K | HLY-ELS26001Y261K |
|---|---|---|---|---|
| Battery energy | 64 kWh | 112 kWh | 157 kWh | 261 kWh |
| Cell | LFP / 3.2 V / 314 Ah | |||
| Nominal voltage | 204.8 V | 358.4 V | 499.2 V | 832 V |
| Battery voltage range | 172.8–233.6 V | 302.4–408.8 V | 421.2–569.4 V | 702–949 V |
| Grid / off-grid rated power | 30 kW | 30 / 50 kW | 30 / 60 kW | 125 kW |
| Grid rated current | 43.5 A | 43.5 / 72.5 A | 43.5 / 87 A | 180.4 / 189.9 A |
| Off-grid maximum current | 48 A | 48 / 80 A | 48 / 96 A | 250 A |
| Battery thermal management | Air cooling | Air cooling | Liquid cooling/heati ng | Liquid cooling/heati ng |
| Maximum PV power | 38.4 + 38.4 kW | 38.4 + 38.4 kW | 38.4 + 38.4 kW | 240 kW |
| Maximum PV voltage | 850 V | 850 V | 850 V | 1,000 V |
Power options depend on configuration; the 261K storage cabinet and PV-integrated model have different dimensions.
| Specification | HLY-ELS06401F64K | HLY-ELS11201F112K | HLY-ELS15601Y157K | HLY-ELS26001Y261K |
|---|---|---|---|---|
| PV start voltage | 250 V | 250 V | 250 V | 180 V |
| MPPT range | 200–800 V | 200–800 V | 200–800 V | 150–950 V |
| Maximum PV current | 64 + 64 A | 64 + 64 A | 64 + 64 A | 10 × 42 A |
| AC voltage | 400 / 230 V | |||
| Frequency | 50±2.5 Hz | 50±2.5 Hz | 50±2.5 Hz | 50 / 60 Hz |
| Overload | 1.1× continuous; 1.2× 1 min | |||
| Grid THDi | <3% | |||
| Off-grid THDu | <3% | <3% | <3% | <2% |
| Adjustable power factor | −1 to +1 | |||
| Grid transfer time | <10 ms | |||
| Fire suppression | Aerosol | |||
| Protection / corrosion class | IP55 / C3; C4, C5 optional | |||
| Operating temperature | −20–55°C | |||
| Humidity | 0–95% RH, non-condensing | |||
Power options depend on configuration; the 261K storage cabinet and PV-integrated model have different dimensions.
| Specification | HLY-ELS06401F64K | HLY-ELS11201F112K | HLY-ELS15601Y157K | HLY-ELS26001Y261K |
|---|---|---|---|---|
| Interfaces / protocols | Ethernet / RS485; Modbus TCP / RTU | |||
| Dimensions W×D×H (mm) | 1,100×900×940 | 1,350×1,160×2,277 | 1,000×1,350×1,880 | 1,000×1,390×2,390 |
| Weight | 900±150 kg | 1,900±150 kg | 1,800±150 kg | 2,600±150 kg |
| Source cycle figure | ≥8,000 @ 0.5C, 25±2°C, EOL ≥70% | |||
| Source-listed standards / documents* | GB/T36276 / IEC62619 / IEC63056 / IEC62477 / IEC61000 / RoHS / UN38.3 / MSDS | |||
Power options depend on configuration; the 261K storage cabinet and PV-integrated model have different dimensions.
“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.
Datasheets and applicable certificates must match your selected model.
Home and factory paths meet in one project brief, then continue on WhatsApp.
WhatsApp +86 182 0104 2779Contact opens the project planner; WhatsApp can carry your prepared brief.