pretty storage
Project-scale systems

Container energy storage.

Start with a project brief covering demand, operating goals, site access, engineering interfaces and the proposed equipment supply boundary.

Concept illustration: Container energy storageConcept illustration · not a model specification
Container energy storage concept visualization
Concept visualization · confirm actual model with our team
ENGINEER THE CONNECTIONS

Plan the system. Define the delivery boundary.

A container project brings equipment, site layout, logistics and engineering interfaces into the same specification.

Review layout, access and the equipment included in the proposed enclosure.

Review your brief →

Prepare for a useful quotation.

01 Project demand profile and connection arrangement

02 Access, foundation and lifting constraints

03 Required drawings, technical documents and arrival schedule

Selection & integration guides

container system architecture ↗container site layout ↗container transport planning ↗container project brief ↗

Define the fit.
Then choose the model.

01

System architecture

Review against the selected model and project requirements.

02

Site planning

Review against the selected model and project requirements.

03

Handling

Review against the selected model and project requirements.

04

Project documents

Review against the selected model and project requirements.

FROM THE SUPPLIED PRODUCT CATALOGUE

Explore equipment in this family.

Container systems

Containerised battery storage for utility, generation-side and large industrial integration.

Rated energy
2.5 MWh / 3.34 MWh / 4.18 MWh / 5 MWh
Rated power (source)
1.25 MW / 1.7 MW / 2.15 MW / 2.5 MW
MV stations

Integrates PCS and a step-up transformer for large energy-storage plants.

Rated / maximum power
5,000 / 5,500 kW
MV stations

Up to 24 battery inputs for cluster-level charge and discharge management.

Rated apparent power
4,464 kVA / 5,160 kVA

Explore the pretty storage product range. Model references identify the technical configurations; availability, branding and OEM / ODM scope are confirmed in the offer.

MODEL DATA, IN CONTEXT

Compare the specifications.

Complete product tables, including the source’s qualifications and missing values.

Liquid-cooled container storageCatalogue pp. 32–33 · 4 listed references

Select a reference for your enquiry

The series and source pages are included in your brief. You can shortlist up to 15 references.

Review your project brief →

Catalogue pp. 32–33 · Original model references retained. Confirm the configuration in the written technical offer.

SOURCE PAGE 32
Liquid-cooled container storage · Model comparison
SpecificationHLY-SLS41606Y2.5MHLY-SLS41608Y3.34MHLY-SLS41610Y4.18MHLY-SLS41612Y5M
Rated energy2.5 MWh3.34 MWh4.18 MWh5 MWh
Rated power (source)1.25 MW1.7 MW2.15 MW2.5 MW
Rated charge / discharge current942 A1,256 A1,570 A1,884 A
Weight≈27 t≈33 t≈38 t≈43 t
Dimensions W×D×H6,058 × 2,438 × 2,896 mm
Cell specificationLFP / 314 Ah / 3.2 V
Rated voltage1,331.2 V DC
Operating voltage1,123.2–1,518.4 V DC
Charge / discharge rate0.5C
Energy efficiency (source)≥92%

Confirm PCS scope and usable SOC window when matching the 1,518.4 V upper limit to 1,500 V PCS equipment.

SOURCE PAGE 33
Liquid-cooled container storage · Model comparison
SpecificationHLY-SLS41606Y2.5MHLY-SLS41608Y3.34MHLY-SLS41610Y4.18MHLY-SLS41612Y5M
Storage temperature−20–40°C
Operating temperature−40–60°C
Humidity≤95%, non-condensing
Thermal managementLiquid cooling, 50% glycol-water
ProtectionIP55
Fire suppressionAerosol / perfluorohexanone (optional)
Protection functionsShort circuit, overcharge/discharge, overtemperature, surge
Fire detection / E-stop / UPSYes / Yes / Yes
Source-listed standards / documents*UN38.3 / MSDS / IEC62933 / EN61000 / IEC62477 / IEC62619 / IEC63056

Confirm PCS scope and usable SOC window when matching the 1,518.4 V upper limit to 1,500 V PCS equipment.

“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.

5 MW skid-mounted MV power stationCatalogue pp. 45–47 · 1 listed references

Select a reference for your enquiry

The series and source pages are included in your brief. You can shortlist up to 15 references.

Review your project brief →

Catalogue pp. 45–47 · Original model references retained. Confirm the configuration in the written technical offer.

SOURCE PAGE 45
5 MW skid-mounted MV power station · Model comparison
SpecificationHLY-900-07P-5000-G
Rated / maximum power5,000 / 5,500 kW
Maximum DC voltage1,500 V
Operating DC voltage1,000–1,500 V
Maximum DC current5,500 A
DC battery inputs3 / 4
Rated grid voltage35 kV
Frequency / tolerance50 Hz / ±5 Hz
Power factor−1 to +1
Grid THDi<3%
Feeders3 / 3+PE

The source 35 kV grid rating and 37 kV equipment figures are retained separately; confirm project connection design.

SOURCE PAGE 46
5 MW skid-mounted MV power station · Model comparison
SpecificationHLY-900-07P-5000-G
Full-power transition<30 ms
Off-grid output37 kV / 5,000 kW / 50 Hz
Off-grid THDu3%, linear load
Overload1.1× continuous; 1.2× 1 min @35°C
Maximum converter efficiency99.05%
TransformerDry-type / Dy11
LV / MV0.69 / 37 kV
DC / AC protectionDisconnector + fuse / circuit breaker
Surge protectionDC Type II / AC Type II
Three-unit W×D×H6,500 × 3,500 × 3,100 mm
Four-unit W×D×H6,600 × 3,400 × 3,154 mm
Cable entryBottom AC and DC
Operating temperature−35–60°C; derate above 45°C
Relative humidity0–100%

The source 35 kV grid rating and 37 kV equipment figures are retained separately; confirm project connection design.

SOURCE PAGE 47
5 MW skid-mounted MV power station · Model comparison
SpecificationHLY-900-07P-5000-G
Altitude5,000 m; derate above 2,000 m
ProtectionPCS:IP65 / other:IP54
CoolingPCS air-water cooling / other natural cooling
InterfacesRS485 / Ethernet / CAN
ProtocolsIEC61850 / Modbus RTU / TCP / EtherCAT / CAN2.0B

The source 35 kV grid rating and 37 kV equipment figures are retained separately; confirm project connection design.

“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.

String-based MV power stationCatalogue pp. 48–50 · 2 listed references

Select a reference for your enquiry

The series and source pages are included in your brief. You can shortlist up to 15 references.

Review your project brief →

Catalogue pp. 48–50 · Original model references retained. Confirm the configuration in the written technical offer.

SOURCE PAGE 48
String-based MV power station · Model comparison
SpecificationHLY-600-07P-4464-GHLY-600-07P-5160-G
Rated apparent power4,464 kVA5,160 kVA
Maximum apparent power4,910 kVA5,676 kVA
Maximum DC current199 A × 24227 A × 24
Maximum DC voltage1,500 V
DC operating / full-load range1,000–1,500 V / 1,050–1,500 V
Battery inputs24
Grid voltage / tolerance35 kV / ±10%
Frequency / tolerance50 Hz / ±5 Hz
Power factor−1 to +1
Grid THDi<3%

The source mixes kVA and kW. Confirm off-grid power and transformer matching for the 4,464 model; no equivalence is assumed.

SOURCE PAGE 49
String-based MV power station · Model comparison
SpecificationHLY-600-07P-4464-GHLY-600-07P-5160-G
Feeders3 / 3+PE
Off-grid voltage / frequency35 kV / 50 Hz
Off-grid rated power (source)4,910 kW5,160 kW
Off-grid THDu3%, linear load
Overload1.1× 4 h; 1.2× 1 min
Transformer rating5,030 kVA5,280 kVA
Transformer type / vector groupOil/dry type; Dy11
MV / LV37 / 0.69 kV
DC protectionDC circuit breaker
AC protectionPCS fuse / MV circuit breaker
Surge protectionDC Type II / AC Type II
Dimensions W×D×H9,700 × 3,400 × 3,200 mm
Cable entryBottom AC and DC
Operating temperature−40–60°C; derate above 45°C
Relative humidity0–95%

The source mixes kVA and kW. Confirm off-grid power and transformer matching for the 4,464 model; no equivalence is assumed.

SOURCE PAGE 50
String-based MV power station · Model comparison
SpecificationHLY-600-07P-4464-GHLY-600-07P-5160-G
Altitude2,000 m
Weight22,000 kg
Protection / coolingIP54 / smart air cooling
InterfacesRS485 / Ethernet / CAN
ProtocolsIEC61850 / Modbus RTU / TCP / CAN2.0B

The source mixes kVA and kW. Confirm off-grid power and transformer matching for the 4,464 model; no equivalence is assumed.

“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.

Review the right documents.

Datasheets and applicable certificates must match your selected model.

Request documentation
BEFORE WE TALK

Good questions.
Clearer decisions.

FACTORY TO YOUR PROJECT

Ready to define your system?

Home and factory paths meet in one project brief, then continue on WhatsApp.

WhatsApp +86 182 0104 2779

Bring your requirements. We’ll help connect the details.

Build your project brief →

Contact opens the project planner; WhatsApp can carry your prepared brief.

WhatsApp