Modular rack batteries for residential solar-storage integration with a compatible inverter.
- Nominal energy
- 10.547 kWh / 14.336 kWh / 16.076 kWh
- Nominal voltage
- 51.2 V
Configure a home battery around essential loads, operating duration and the selected inverter. Appearance, mounting and expansion options are confirmed by model.
Discuss this system
Concept illustration · not a model specification
Concept visualization · confirm actual model with our teamExplore wall, stack and rack directions, then review the loads, inverter pairing and installation conditions for your home-system brief.
Discuss the supported module layout and future expansion path.
Review your brief →01 Priority circuits and their running / starting demand
02 Desired backup period and available solar
03 Photographs and dimensions of the proposed installation area
Review against the selected model and project requirements.
Review against the selected model and project requirements.
Review against the selected model and project requirements.
Review against the selected model and project requirements.
Modular rack batteries for residential solar-storage integration with a compatible inverter.
A 51.2 V battery platform selected by energy capacity and installation format.
Choose a stacked, rack or upright enclosure for the available installation space.
Modular capacity options for household solar consumption and backup planning.
Low-voltage cabinet batteries for integration with a compatible inverter.
Integrated inverter and battery: compare PV input, battery energy and AC output separately.
Explore the pretty storage product range. Model references identify the technical configurations; availability, branding and OEM / ODM scope are confirmed in the offer.
Complete product tables, including the source’s qualifications and missing values.
The series and source pages are included in your brief. You can shortlist up to 15 references.
Review your project brief →Catalogue pp. 5–6 · Original model references retained. Confirm the configuration in the written technical offer.
| Specification | LNFZ-R-10KWh | LNFZ-R-14KWh | LNFZ C-51J314 |
|---|---|---|---|
| Nominal energy | 10.547 kWh | 14.336 kWh | 16.076 kWh |
| Rated capacity | 206 Ah | 280 Ah | 314 Ah |
| Nominal voltage | 51.2 V | ||
| Charge cut-off | 58.4 V | ||
| Operating voltage | 40–58.4 V | ||
| Discharge cut-off | 40 V | ||
| Standard charge current | 61 A | 140 A | 150 A |
| Standard discharge current | 103 A | 140 A | 150 A |
| Dimensions W/H/D (mm) | 408/602/285 | 408/717/285 | 408/717/285 |
| Weight | 78.3 kg | 106 kg | 109.8 kg |
Cycle end-of-life criterion is not supplied. Confirm the source dimension order against the installation drawing.
| Specification | LNFZ-R-10KWh | LNFZ-R-14KWh | LNFZ C-51J314 |
|---|---|---|---|
| Chemistry / configuration | LFP / 1P16S | ||
| Ingress protection | IP21 | ||
| Altitude | <2,000 m | ||
| Charge temperature | 0–55°C | ||
| Discharge temperature | −10–60°C | ||
| Storage humidity | 5–70% RH | ||
| Communication | CAN / RS485 | ||
| Source cycle figure | 6,000 @ 0.5C, 80% DOD, 25°C | ||
Cycle end-of-life criterion is not supplied. Confirm the source dimension order against the installation drawing.
“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.
The series and source pages are included in your brief. You can shortlist up to 15 references.
Review your project brief →Catalogue pp. 7–8 · Original model references retained. Confirm the configuration in the written technical offer.
| Specification | LNFZ-W-5KWh | LNFZ-F-10KWh |
|---|---|---|
| Nominal energy (kWh) | 5.120 | 10.547 |
| Capacity (Ah) | 100 | 206 |
| Nominal voltage | 51.2 V | |
| Operating voltage | 40–58.4 V | |
| Charge / discharge cut-off | 58.4 / 40 V | |
| Standard charge current (A) | 50 | 61 |
| Standard discharge current (A) | 100 | 103 |
| Dimensions W/H/D (mm) | 432/214/492 | 500/280/626 |
| Weight (kg) | 44.6 | 80 |
| Chemistry / configuration | LFP / 1P16S | |
| Protection / altitude | IP21 / <2,000 m | |
| Charge / discharge temperature | 0–45°C / −20–55°C | |
| Storage humidity | 5–70% RH | |
| Communication | CAN / RS485 | |
| Source cycle figure | 6,000 @ 0.5C, 80% DOD, 25°C | |
Series illustration. Confirm dimension order and cycle end-of-life criterion.
| Specification | LNFZ-F-14KWh | LNFZ-F-16KWh |
|---|---|---|
| Nominal energy (kWh) | 14.336 | 16.076 |
| Capacity (Ah) | 280 | 314 |
| Nominal voltage | 51.2 V | |
| Operating voltage | 40–58.4 V | |
| Charge / discharge cut-off | 58.4 / 40 V | |
| Standard charge current (A) | 140 | 150 |
| Standard discharge current (A) | 140 | 150 |
| Dimensions W/H/D (mm) | 408/326/842 | 825/420/345 |
| Weight (kg) | 110 | 113 |
| Chemistry / configuration | LFP / 1P16S | |
| Protection / altitude | IP21 / <2,000 m | |
| Charge / discharge temperature | 0–45°C / −20–55°C | |
| Storage humidity | 5–70% RH | |
| Communication | CAN / RS485 | |
| Source cycle figure | 6,000 @ 0.5C, 80% DOD, 25°C | |
Series illustration. Confirm dimension order and cycle end-of-life criterion.
“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.
The series and source pages are included in your brief. You can shortlist up to 15 references.
Review your project brief →Catalogue pp. 9 · Original model references retained. Confirm the configuration in the written technical offer.
| Specification | Stacked | Rack | Upright |
|---|---|---|---|
| Catalogue energy range | 15–16 kWh | 15–16 kWh | 30–32 kWh |
| Voltage family | 48 V | ||
| Model / full electrical data | To confirm | ||
| Dimensions / weight / interfaces | To confirm | ||
Overview data only; LNFZ or HLY specifications must not be substituted.
“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.
The series and source pages are included in your brief. You can shortlist up to 15 references.
Review your project brief →Catalogue pp. 10 · Original model references retained. Confirm the configuration in the written technical offer.
| Specification | 5K | 10K | 15K | 20K | 25K |
|---|---|---|---|---|---|
| System energy | 5.12 kWh | 10.24 kWh | 15.36 kWh | 20.48 kWh | 25.60 kWh |
| Full model | HLY-DLS01601Z*K-V1.0 | ||||
| Cell specification | LFP / 100 Ah / 3.2 V | ||||
| Nominal battery voltage | 51.2 V DC | ||||
| Charge / discharge rate | 0.5C | ||||
| Charge / discharge cut-off | 58.4 / 43.2 V | ||||
| Paired AC voltage | 220 / 230 / 240 V AC | ||||
| Paired inverter power | 6 / 12 kW; confirm configuration | ||||
| Operating temperature | −20–40°C | ||||
| Storage temperature | −30–50°C | ||||
| Humidity | ≤95%, non-condensing | ||||
| Protection | Overcurrent, overcharge/discharge, overtemperature, short circuit | ||||
| Balancing | Yes | ||||
| Source cycle figure | ≥8,000 @ 0.5C, 25±2°C, EOL ≥70% | ||||
| Source-listed standards / documents* | IEC62619 / IEC61000-6-3 / IEC61000-6-1 / UN38.3 / MSDS | ||||
The 6/12 kW and AC voltage figures apply with a paired inverter, not to the battery alone.
“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.
The series and source pages are included in your brief. You can shortlist up to 15 references.
Review your project brief →Catalogue pp. 11–12 · Original model references retained. Confirm the configuration in the written technical offer.
| Specification | HLY-DLS01601Z10.5K | HLY-DLS01601Z14.3K | HLY-DLS01601Z16K |
|---|---|---|---|
| Nominal energy | 10.5 kWh | 14.3 kWh | 16 kWh |
| LFP cell capacity | 205 Ah | 280 Ah | 314 Ah |
| Battery configuration | 1P16S | ||
| W×D×H excluding castors | 570.4 × 328.8 × 734.6 mm | ||
| Weight | ≈120 kg | ≈140 kg | ≈140 kg |
| Nominal voltage | 51.2 V | ||
| Charge / discharge cut-off | 58.4 / 43.2 V | ||
| Communication | CAN / RS485 / Bluetooth | ||
| Ingress protection | IP54 | ||
| Operating temperature | −20–40°C | ||
The source reuses these model codes for the all-in-one series. Specify battery-only or all-in-one when enquiring.
| Specification | HLY-DLS01601Z10.5K | HLY-DLS01601Z14.3K | HLY-DLS01601Z16K |
|---|---|---|---|
| Altitude | <1,000 m | ||
| Humidity | ≤95%, non-condensing | ||
| Source cycle figure | ≥8,000 @ 0.5C, 25±2°C, EOL ≥70% | ||
| Storage temperature | −30–50°C | ||
| Enclosure material | 1.5 mm carbon steel | ||
| Enclosure finish | Signal white, textured | ||
| Source-listed standards / documents* | IEC62619 / IEC61000 / UN38.3 / MSDS | ||
The source reuses these model codes for the all-in-one series. Specify battery-only or all-in-one when enquiring.
“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.
The series and source pages are included in your brief. You can shortlist up to 15 references.
Review your project brief →Catalogue pp. 13–14 · Original model references retained. Confirm the configuration in the written technical offer.
| Specification | HLY-DLS01601Z10.5K | HLY-DLS01601Z14.3K | HLY-DLS01601Z16K |
|---|---|---|---|
| Battery energy | 10.5 kWh | 14.3 kWh | 16 kWh |
| LFP cell capacity | 205 Ah | 280 Ah | 314 Ah |
| Rated AC power | 5 kW | 7 kW | 8 kW |
| AC input / output current | 22.7 A | 31.8 A | 36.4 A |
| Rated battery discharge current | 100 A | 140 A | 157 A |
| MPPT trackers | 1 | 2 | 2 |
| Maximum PV voltage | 500 V | ||
| MPPT voltage range | 85–450 V | ||
| PV rated / start voltage | 380 / 75 V | ||
| AC input voltage | 90–280 V | ||
Source model codes overlap with battery-only cabinets; specify the all-in-one configuration.
| Specification | HLY-DLS01601Z10.5K | HLY-DLS01601Z14.3K | HLY-DLS01601Z16K |
|---|---|---|---|
| AC input frequency range | 40–65 Hz | ||
| AC output voltage | 220 / 230 / 240 V | ||
| Rated frequency | 50 / 60 Hz | ||
| Transfer time | 10 ms | ||
| W×D×H excluding castors | 700 × 245 × 1,200 mm | ||
| Weight | ≈135 kg | ≈156 kg | ≈165 kg |
| Nominal voltage | 51.2 V | ||
| Charge / discharge cut-off | 58.4 / 43.2 V | ||
| Communication | CAN / RS485 / Bluetooth | ||
| Ingress protection | IP54 | ||
| Operating temperature | −20–40°C | ||
| Altitude | <1,000 m | ||
| Humidity | ≤95%, non-condensing | ||
| Source cycle figure | ≥8,000 @ 0.5C, 25±2°C, EOL ≥70% | ||
| Source-listed standards / documents* | IEC62619 / IEC61000 / UN38.3 / MSDS | ||
Source model codes overlap with battery-only cabinets; specify the all-in-one configuration.
“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.
Datasheets and applicable certificates must match your selected model.
Home and factory paths meet in one project brief, then continue on WhatsApp.
WhatsApp +86 182 0104 2779Contact opens the project planner; WhatsApp can carry your prepared brief.