Supports unbalanced three-phase loads and power-quality management.
- Rated / maximum AC power
- 100 / 110 kW
Review the site supply, operating mode, load profile and battery pairing. Confirm the exact model and supported configuration before ordering.
Discuss this system
Concept illustration · not a model specification
Concept visualization · confirm actual model with our teamReview supply arrangement, operating mode, battery communication and monitoring as one integration conversation.
Agree monitoring access, communications and the information your team needs.
Review your brief →01 Site supply arrangement and intended operating modes
02 Existing battery or solar equipment model references
03 Load list, including motors and priority circuits
Review against the selected model and project requirements.
Review against the selected model and project requirements.
Review against the selected model and project requirements.
Review against the selected model and project requirements.
Supports unbalanced three-phase loads and power-quality management.
Independent cooling ducts for high-voltage battery systems and multi-unit configurations.
High-voltage battery interface with three-phase output and remote monitoring.
For off-grid and backup systems: 4 kW uses a 24 V battery, while 6/12 kW use 48 V.
Explore the pretty storage product range. Model references identify the technical configurations; availability, branding and OEM / ODM scope are confirmed in the offer.
Complete product tables, including the source’s qualifications and missing values.
The series and source pages are included in your brief. You can shortlist up to 15 references.
Review your project brief →Catalogue pp. 34–35 · Original model references retained. Confirm the configuration in the written technical offer.
| Specification | HLY-1000-M-04/100-SKWN |
|---|---|
| Rated / maximum AC power | 100 / 110 kW |
| Maximum DC power | 110 kW |
| Maximum DC voltage | 1,000 V |
| DC voltage range | 680–1,000 V |
| Maximum DC current | 162 A |
| Rated / maximum AC current | 152 / 167 A |
| AC voltage | 380 V |
| Grid voltage range | 323–418 V |
| AC wiring | Three-phase four-wire, transformerless |
| Reactive power | −100 to +100 kvar |
Figures apply to the listed models. Options, operating conditions and supply scope are defined in the technical agreement.
| Specification | HLY-1000-M-04/100-SKWN |
|---|---|
| Rated frequency / tolerance | 50 Hz / ±5 Hz |
| Charge/discharge transition | <20 ms |
| Off-grid output | 380 V / 100 kW / 50 Hz |
| Maximum efficiency | 98.5% |
| Overload | 1.1× continuous @45°C; 1.2× 1 min; 1.3× 1 s |
| Cable entry | Top DC entry; front AC exit |
| Ambient temperature | −30–60°C; derate above 50°C |
| Relative humidity | 0–100% RH |
| Altitude | 4,000 m; derate above 2,000 m |
| Noise | ≤75 dB @1 m, full load |
| Dimensions W×D×H | 250 × 750 × 680 mm |
| Weight | 85 kg |
| Protection / cooling | IP65 / water cooling |
| Communication interfaces | RS485 / Ethernet / EtherCAT / CAN |
| Protocols | Modbus RTU / TCP / CAN2.0B / IEC61850 |
Figures apply to the listed models. Options, operating conditions and supply scope are defined in the technical agreement.
“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.
The series and source pages are included in your brief. You can shortlist up to 15 references.
Review your project brief →Catalogue pp. 36–38 · Original model references retained. Confirm the configuration in the written technical offer.
| Specification | HLY-600-07-186 | HLY-600-07-215 |
|---|---|---|
| Rated AC power | 186 kW | 215 kW |
| Maximum AC power | 205 kW | 237 kW |
| Maximum DC power | 209 kW | 241 kW |
| Maximum DC current | 199 A | 230 A |
| Maximum / operating DC voltage | 1,500 V / 1,000–1,500 V | |
| Rated / maximum AC current | 156 / 172 A | 180 / 198 A |
| Reactive power | ±196 kvar | ±226 kvar |
| AC wiring / isolation | Three-phase three-wire, non-isolated | |
| Rated / operating grid voltage | 690 V / 621–759 V | |
| Rated frequency / tolerance | 50 Hz / ±5 Hz | |
Figures apply to the listed models. Options, operating conditions and supply scope are defined in the technical agreement.
| Specification | HLY-600-07-186 | HLY-600-07-215 |
|---|---|---|
| Power factor | −1 to +1 | |
| Charge/discharge transition | <30 ms | |
| Off-grid voltage | 690 V, configurable | |
| Off-grid voltage deviation | <1% Un, balanced linear load | |
| Voltage unbalance | <2%, 4% transient | |
| Off-grid THDu | <3%, linear load | |
| DC component | <0.1% Un | |
| Maximum efficiency | 99% | |
| Overload | 1.1× continuous @45°C; 1.2× >1 min | |
| Ambient temperature | −40–60°C; derate above 50°C | |
| Relative humidity | 0–100% | |
| Altitude | 5,000 m; derate above 4,000 m | |
| Noise | <75 dB | |
| Dimensions W×D×H | 275 × 640 × 840 mm | |
| Weight | <100 kg | |
Figures apply to the listed models. Options, operating conditions and supply scope are defined in the technical agreement.
| Specification | HLY-600-07-186 | HLY-600-07-215 |
|---|---|---|
| Protection / cooling | IP66 / smart air cooling | |
| Cable entry | Bottom | |
| Interfaces | RS485 / CAN / Ethernet / DIO | |
| Display | LED | |
| Protocols | Modbus RTU / CAN2.0B / EtherCAT | |
Figures apply to the listed models. Options, operating conditions and supply scope are defined in the technical agreement.
“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.
The series and source pages are included in your brief. You can shortlist up to 15 references.
Review your project brief →Catalogue pp. 39–41 · Original model references retained. Confirm the configuration in the written technical offer.
| Specification | HLY-10KH3 | HLY-12KH3 | HLY-15KH3 |
|---|---|---|---|
| Rated AC power | 10 kW | 12 kW | 15 kW |
| Rated AC current | 14.5 A | 17.4 A | 21.7 A |
| Instantaneous peak output | 11 kVA | 13.2 kVA | 16.5 kVA |
| Recommended max PV power (source) | 22.8 kW | ||
| Maximum PV voltage | 1,000 V | ||
| MPPT range / start voltage | 200–850 V / 200 V | ||
| MPPT trackers / strings | 2 / 1+2 | ||
| MPPT max / short-circuit current | 15+30 A / 19.5+40 A | ||
| AC voltage / wiring | 400 V / L1,L2,L3,N,PE | ||
| Frequency | 50 / 60 Hz | ||
The source appears to mislabel 99.9% and 98% efficiency fields; values are not silently reassigned. Warranty is contractual.
| Specification | HLY-10KH3 | HLY-12KH3 | HLY-15KH3 |
|---|---|---|---|
| THDi | <3% | ||
| Power factor (source) | −0.8 to +0.8 | ||
| Battery type | Lead-acid / LFP | ||
| Battery voltage range / nominal | 160–800 V / 400 V | ||
| Maximum battery charge/discharg e | 50 A | ||
| Battery communication | RS485 / CAN | ||
| Transfer time | <10 ms | ||
| European efficiency | 97.5% | ||
| Battery charge/discharge efficiency | 97% | ||
| Peak / MPPT efficiency | Source labels misaligned; to confirm | ||
| Protection | PV/battery reverse polarity, short circuit, overvoltage, insulation, leakage, anti-islanding | ||
| Surge protection | PV Type III / AC Type III | ||
| Protection | IP65 | ||
| Temperature / humidity | −20–60°C / 10–90% RH | ||
| Mounting / cooling | Wall mount / smart cooling | ||
The source appears to mislabel 99.9% and 98% efficiency fields; values are not silently reassigned. Warranty is contractual.
| Specification | HLY-10KH3 | HLY-12KH3 | HLY-15KH3 |
|---|---|---|---|
| Communication / display | Wi-Fi / RS485 / CAN / GPRS; LCD / APP | ||
| Dimensions L×W×H | 480 × 425 × 202 mm | ||
| Net weight | 25 kg | 26 kg | 27 kg |
| Package dimensions | 637 × 545 × 326 mm | ||
| Gross weight | 29 kg | 30 kg | 31 kg |
The source appears to mislabel 99.9% and 98% efficiency fields; values are not silently reassigned. Warranty is contractual.
“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.
The series and source pages are included in your brief. You can shortlist up to 15 references.
Review your project brief →Catalogue pp. 42–44 · Original model references retained. Confirm the configuration in the written technical offer.
| Specification | HLY-4K-SF EU | HLY-6K-SF EU | HLY-12K-SF EU |
|---|---|---|---|
| Rated off-grid power | 4 kW | 6 kW | 12 kW |
| Rated output current | 18.2 A | 27.3 A | 54.5 A |
| Peak output for 5 s | 8 kVA | 12 kVA | 24 kVA |
| Recommended max PV power | 4 kW | 6 kW | 12 kW |
| Maximum PV voltage | 500 V | ||
| MPPT range | 85–450 V | ||
| PV start voltage | 85 V | 75 V | 75 V |
| MPPT trackers | 1 | 1 | 2 |
| Strings per MPPT | 1 | ||
| MPPT maximum current | 15 A | 27 A | 27 / 27 A |
The source MPPT field contains a percentage; presented as efficiency. Confirm warranty and battery compatibility.
| Specification | HLY-4K-SF EU | HLY-6K-SF EU | HLY-12K-SF EU |
|---|---|---|---|
| MPPT short-circuit current | 18 A | 35 A | 35 / 35 A |
| Maximum AC input power | 5 kW | 11.5 kW | 16 kW |
| Maximum AC input current | 28 A | 50 A | 90 A |
| AC voltage / frequency | 220 / 230 / 240 V; 50 / 60 Hz | ||
| AC input range | UPS:170–280 V; load mode:90–280 V | ||
| Battery type | LFP / lead-acid | ||
| Battery range / nominal voltage | 20–30 / 24 V DC | 40–60 / 48 V DC | 40–60 / 48 V DC |
| Maximum charge / discharge current | 120 / 160 A | 120 / 130 A | 210 / 230 A |
| Battery communication | RS485 | ||
| Parallel operation | Not supported | Up to 12 units | Up to 12 units |
| THDi (linear load) | <3% | ||
| Transfer time | UPS:10 ms; load mode:20 ms | ||
| Peak efficiency | 95% | 98% | 98% |
| MPPT efficiency (source) | 99.9% | ||
| Standby consumption | <10 W | <10 W | <20 W |
| Protection | IP54 | ||
| Temperature / humidity | −10–55°C / 5–95% RH | ||
The source MPPT field contains a percentage; presented as efficiency. Confirm warranty and battery compatibility.
| Specification | HLY-4K-SF EU | HLY-6K-SF EU | HLY-12K-SF EU |
|---|---|---|---|
| Altitude | Derate above 2,000 m | ||
| Mounting / cooling | Wall mount / air cooling | ||
| Communication / display | RS232 / RS485 / dry contact / Wi-Fi; LCD | ||
| Dimensions L×W×H (mm) | 444.7×346.6×120 | 444.7×346.6×120 | 630×525×125 |
| Net weight | 9.2 kg | 12.4 kg | 28.5 kg |
| Package dimensions (mm) | 560×465×240 | 560×465×240 | 745×650×240 |
| Gross weight | 11.4 kg | 14.6 kg | 32 kg |
The source MPPT field contains a percentage; presented as efficiency. Confirm warranty and battery compatibility.
“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.
Datasheets and applicable certificates must match your selected model.
Home and factory paths meet in one project brief, then continue on WhatsApp.
WhatsApp +86 182 0104 2779Contact opens the project planner; WhatsApp can carry your prepared brief.