pretty storage
Power conversion

Hybrid inverters.

Review the site supply, operating mode, load profile and battery pairing. Confirm the exact model and supported configuration before ordering.

Concept illustration: Hybrid invertersConcept illustration · not a model specification
Hybrid inverters concept visualization
Concept visualization · confirm actual model with our team
ENGINEER THE CONNECTIONS

The connection between generation, storage and loads.

Review supply arrangement, operating mode, battery communication and monitoring as one integration conversation.

Agree monitoring access, communications and the information your team needs.

Review your brief →

Prepare for a useful quotation.

01 Site supply arrangement and intended operating modes

02 Existing battery or solar equipment model references

03 Load list, including motors and priority circuits

Selection & integration guides

single phase inverter selection ↗three phase inverter selection ↗inverter battery compatibility ↗inverter monitoring interfaces ↗

Define the fit.
Then choose the model.

01

Phase arrangement

Review against the selected model and project requirements.

02

Operating modes

Review against the selected model and project requirements.

03

Battery pairing

Review against the selected model and project requirements.

04

Communication

Review against the selected model and project requirements.

FROM THE SUPPLIED PRODUCT CATALOGUE

Explore equipment in this family.

PCS & inverters

Supports unbalanced three-phase loads and power-quality management.

Rated / maximum AC power
100 / 110 kW
PCS & inverters

Independent cooling ducts for high-voltage battery systems and multi-unit configurations.

Rated AC power
186 kW / 215 kW
PCS & inverters

High-voltage battery interface with three-phase output and remote monitoring.

Rated AC power
10 kW / 12 kW / 15 kW
PCS & inverters

For off-grid and backup systems: 4 kW uses a 24 V battery, while 6/12 kW use 48 V.

Rated off-grid power
4 kW / 6 kW / 12 kW

Explore the pretty storage product range. Model references identify the technical configurations; availability, branding and OEM / ODM scope are confirmed in the offer.

MODEL DATA, IN CONTEXT

Compare the specifications.

Complete product tables, including the source’s qualifications and missing values.

100 kW liquid-cooled PCSCatalogue pp. 34–35 · 1 listed references

Select a reference for your enquiry

The series and source pages are included in your brief. You can shortlist up to 15 references.

Review your project brief →

Catalogue pp. 34–35 · Original model references retained. Confirm the configuration in the written technical offer.

SOURCE PAGE 34
100 kW liquid-cooled PCS · Model comparison
SpecificationHLY-1000-M-04/100-SKWN
Rated / maximum AC power100 / 110 kW
Maximum DC power110 kW
Maximum DC voltage1,000 V
DC voltage range680–1,000 V
Maximum DC current162 A
Rated / maximum AC current152 / 167 A
AC voltage380 V
Grid voltage range323–418 V
AC wiringThree-phase four-wire, transformerless
Reactive power−100 to +100 kvar

Figures apply to the listed models. Options, operating conditions and supply scope are defined in the technical agreement.

SOURCE PAGE 35
100 kW liquid-cooled PCS · Model comparison
SpecificationHLY-1000-M-04/100-SKWN
Rated frequency / tolerance50 Hz / ±5 Hz
Charge/discharge transition<20 ms
Off-grid output380 V / 100 kW / 50 Hz
Maximum efficiency98.5%
Overload1.1× continuous @45°C; 1.2× 1 min; 1.3× 1 s
Cable entryTop DC entry; front AC exit
Ambient temperature−30–60°C; derate above 50°C
Relative humidity0–100% RH
Altitude4,000 m; derate above 2,000 m
Noise≤75 dB @1 m, full load
Dimensions W×D×H250 × 750 × 680 mm
Weight85 kg
Protection / coolingIP65 / water cooling
Communication interfacesRS485 / Ethernet / EtherCAT / CAN
ProtocolsModbus RTU / TCP / CAN2.0B / IEC61850

Figures apply to the listed models. Options, operating conditions and supply scope are defined in the technical agreement.

“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.

186 / 215 kW string PCSCatalogue pp. 36–38 · 2 listed references

Select a reference for your enquiry

The series and source pages are included in your brief. You can shortlist up to 15 references.

Review your project brief →

Catalogue pp. 36–38 · Original model references retained. Confirm the configuration in the written technical offer.

SOURCE PAGE 36
186 / 215 kW string PCS · Model comparison
SpecificationHLY-600-07-186HLY-600-07-215
Rated AC power186 kW215 kW
Maximum AC power205 kW237 kW
Maximum DC power209 kW241 kW
Maximum DC current199 A230 A
Maximum / operating DC voltage1,500 V / 1,000–1,500 V
Rated / maximum AC current156 / 172 A180 / 198 A
Reactive power±196 kvar±226 kvar
AC wiring / isolationThree-phase three-wire, non-isolated
Rated / operating grid voltage690 V / 621–759 V
Rated frequency / tolerance50 Hz / ±5 Hz

Figures apply to the listed models. Options, operating conditions and supply scope are defined in the technical agreement.

SOURCE PAGE 37
186 / 215 kW string PCS · Model comparison
SpecificationHLY-600-07-186HLY-600-07-215
Power factor−1 to +1
Charge/discharge transition<30 ms
Off-grid voltage690 V, configurable
Off-grid voltage deviation<1% Un, balanced linear load
Voltage unbalance<2%, 4% transient
Off-grid THDu<3%, linear load
DC component<0.1% Un
Maximum efficiency99%
Overload1.1× continuous @45°C; 1.2× >1 min
Ambient temperature−40–60°C; derate above 50°C
Relative humidity0–100%
Altitude5,000 m; derate above 4,000 m
Noise<75 dB
Dimensions W×D×H275 × 640 × 840 mm
Weight<100 kg

Figures apply to the listed models. Options, operating conditions and supply scope are defined in the technical agreement.

SOURCE PAGE 38
186 / 215 kW string PCS · Model comparison
SpecificationHLY-600-07-186HLY-600-07-215
Protection / coolingIP66 / smart air cooling
Cable entryBottom
InterfacesRS485 / CAN / Ethernet / DIO
DisplayLED
ProtocolsModbus RTU / CAN2.0B / EtherCAT

Figures apply to the listed models. Options, operating conditions and supply scope are defined in the technical agreement.

“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.

Three-phase HV hybrid invertersCatalogue pp. 39–41 · 3 listed references

Select a reference for your enquiry

The series and source pages are included in your brief. You can shortlist up to 15 references.

Review your project brief →

Catalogue pp. 39–41 · Original model references retained. Confirm the configuration in the written technical offer.

SOURCE PAGE 39
Three-phase HV hybrid inverters · Model comparison
SpecificationHLY-10KH3HLY-12KH3HLY-15KH3
Rated AC power10 kW12 kW15 kW
Rated AC current14.5 A17.4 A21.7 A
Instantaneous peak output11 kVA13.2 kVA16.5 kVA
Recommended max PV power (source)22.8 kW
Maximum PV voltage1,000 V
MPPT range / start voltage200–850 V / 200 V
MPPT trackers / strings2 / 1+2
MPPT max / short-circuit current15+30 A / 19.5+40 A
AC voltage / wiring400 V / L1,L2,L3,N,PE
Frequency50 / 60 Hz

The source appears to mislabel 99.9% and 98% efficiency fields; values are not silently reassigned. Warranty is contractual.

SOURCE PAGE 40
Three-phase HV hybrid inverters · Model comparison
SpecificationHLY-10KH3HLY-12KH3HLY-15KH3
THDi<3%
Power factor (source)−0.8 to +0.8
Battery typeLead-acid / LFP
Battery voltage range / nominal160–800 V / 400 V
Maximum battery charge/discharg e50 A
Battery communicationRS485 / CAN
Transfer time<10 ms
European efficiency97.5%
Battery charge/discharge efficiency97%
Peak / MPPT efficiencySource labels misaligned; to confirm
ProtectionPV/battery reverse polarity, short circuit, overvoltage, insulation, leakage, anti-islanding
Surge protectionPV Type III / AC Type III
ProtectionIP65
Temperature / humidity−20–60°C / 10–90% RH
Mounting / coolingWall mount / smart cooling

The source appears to mislabel 99.9% and 98% efficiency fields; values are not silently reassigned. Warranty is contractual.

SOURCE PAGE 41
Three-phase HV hybrid inverters · Model comparison
SpecificationHLY-10KH3HLY-12KH3HLY-15KH3
Communication / displayWi-Fi / RS485 / CAN / GPRS; LCD / APP
Dimensions L×W×H480 × 425 × 202 mm
Net weight25 kg26 kg27 kg
Package dimensions637 × 545 × 326 mm
Gross weight29 kg30 kg31 kg

The source appears to mislabel 99.9% and 98% efficiency fields; values are not silently reassigned. Warranty is contractual.

“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.

Single-phase off-grid invertersCatalogue pp. 42–44 · 3 listed references

Select a reference for your enquiry

The series and source pages are included in your brief. You can shortlist up to 15 references.

Review your project brief →

Catalogue pp. 42–44 · Original model references retained. Confirm the configuration in the written technical offer.

SOURCE PAGE 42
Single-phase off-grid inverters · Model comparison
SpecificationHLY-4K-SF EUHLY-6K-SF EUHLY-12K-SF EU
Rated off-grid power4 kW6 kW12 kW
Rated output current18.2 A27.3 A54.5 A
Peak output for 5 s8 kVA12 kVA24 kVA
Recommended max PV power4 kW6 kW12 kW
Maximum PV voltage500 V
MPPT range85–450 V
PV start voltage85 V75 V75 V
MPPT trackers112
Strings per MPPT1
MPPT maximum current15 A27 A27 / 27 A

The source MPPT field contains a percentage; presented as efficiency. Confirm warranty and battery compatibility.

SOURCE PAGE 43
Single-phase off-grid inverters · Model comparison
SpecificationHLY-4K-SF EUHLY-6K-SF EUHLY-12K-SF EU
MPPT short-circuit current18 A35 A35 / 35 A
Maximum AC input power5 kW11.5 kW16 kW
Maximum AC input current28 A50 A90 A
AC voltage / frequency220 / 230 / 240 V; 50 / 60 Hz
AC input rangeUPS:170–280 V; load mode:90–280 V
Battery typeLFP / lead-acid
Battery range / nominal voltage20–30 / 24 V DC40–60 / 48 V DC40–60 / 48 V DC
Maximum charge / discharge current120 / 160 A120 / 130 A210 / 230 A
Battery communicationRS485
Parallel operationNot supportedUp to 12 unitsUp to 12 units
THDi (linear load)<3%
Transfer timeUPS:10 ms; load mode:20 ms
Peak efficiency95%98%98%
MPPT efficiency (source)99.9%
Standby consumption<10 W<10 W<20 W
ProtectionIP54
Temperature / humidity−10–55°C / 5–95% RH

The source MPPT field contains a percentage; presented as efficiency. Confirm warranty and battery compatibility.

SOURCE PAGE 44
Single-phase off-grid inverters · Model comparison
SpecificationHLY-4K-SF EUHLY-6K-SF EUHLY-12K-SF EU
AltitudeDerate above 2,000 m
Mounting / coolingWall mount / air cooling
Communication / displayRS232 / RS485 / dry contact / Wi-Fi; LCD
Dimensions L×W×H (mm)444.7×346.6×120444.7×346.6×120630×525×125
Net weight9.2 kg12.4 kg28.5 kg
Package dimensions (mm)560×465×240560×465×240745×650×240
Gross weight11.4 kg14.6 kg32 kg

The source MPPT field contains a percentage; presented as efficiency. Confirm warranty and battery compatibility.

“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.

Review the right documents.

Datasheets and applicable certificates must match your selected model.

Request documentation
BEFORE WE TALK

Good questions.
Clearer decisions.

FACTORY TO YOUR PROJECT

Ready to define your system?

Home and factory paths meet in one project brief, then continue on WhatsApp.

WhatsApp +86 182 0104 2779

Bring your requirements. We’ll help connect the details.

Build your project brief →

Contact opens the project planner; WhatsApp can carry your prepared brief.

WhatsApp