Transportable PV, battery and diesel configurations for temporary and off-grid power.
- PV array power
- 18 kWp / 30.7 kWp
Share the installation area and system brief. Module dimensions, electrical parameters and mounting need to work with the proposed array and inverter.
Discuss this system
Concept illustration · not a model specificationPlan dimensions, electrical limits and mounting together.
Bring the available area, installation surface and system objective together before selecting the module and string arrangement.
Panel dimensions and roof obstructions determine how equipment can be arranged.
Review your brief →01 Roof or site layout with usable dimensions
02 Proposed inverter model, if already selected
03 Destination and intended operating mode
Review against the selected model and project requirements.
Review against the selected model and project requirements.
Review against the selected model and project requirements.
Review against the selected model and project requirements.
Transportable PV, battery and diesel configurations for temporary and off-grid power.
Combine a foldable PV array and storage; plan deployment around footprint and setup time.
Transportable foldable PV arrays for larger temporary generation and storage-integrated projects.
Explore the pretty storage product range. Model references identify the technical configurations; availability, branding and OEM / ODM scope are confirmed in the offer.
Complete product tables, including the source’s qualifications and missing values.
The series and source pages are included in your brief. You can shortlist up to 15 references.
Review your project brief →Catalogue pp. 51–53 · Original model references retained. Confirm the configuration in the written technical offer.
| Specification | HLY-08GP-M-18K20 | HLY-10GP-M-30K40 |
|---|---|---|
| PV array power | 18 kWp | 30.7 kWp |
| Total weight | 5.5 t | 6.5 t |
| Deployed dimensions | 53 × 2.2 × 0.5 m | 69 × 2.4 × 0.8 m |
| Folded dimensions | 2.2 × 1.4 × 1.7 m | 2.2 × 1.5 × 2.1 m |
| Maximum slope | 1% | |
| Orientation | Any azimuth | |
| Deployment time | 50 min | 60 min |
| Container type | 8GP | 10GP |
| Container L×W×H (mm) | 2,900×2,200×2,200 | 2,991×2,438×2,591 |
| Container weight | 1.6 t | 2.5 t |
The 30K40 model designation does not reconcile with the battery count; SU-10k is also listed at 12 kW. Confirm the bill of materials.
| Specification | HLY-08GP-M-18K20 | HLY-10GP-M-30K40 |
|---|---|---|
| Inverter model (source) | SU-10k | |
| Inverter type | Grid-connected | |
| Inverter quantity | 2 | 3 |
| Inverter max input per unit | 13,000 Wp | 15,600 Wp |
| Rated / max AC per unit | 10 / 11 kW | 12 / 13.2 kW |
| AC voltage / frequency | 3L/N/PE 220/380, 230/400 V; 50/60 Hz | |
| Maximum output current per unit | 16.7 / 15.9 A | 20 / 19.1 A |
| Inverter dimensions W×H×D | 422 × 702 × 281 mm | |
| Inverter weight | 33.6 kg | |
| Inverter temperature (source) | 25–65°C; lower limit to confirm | |
| Inverter communication | RS485 / RS232 / Wi-Fi / LAN | |
| Battery module | LFP 10kWh / LV | |
| Battery capacity / voltage per set | 200 Ah / 51.2 V DC | |
| Battery energy | Source:10.24 kW; unit to confirm | |
| Battery sets | 2 | 2 |
| Battery charge / peak discharge | 5 kW / 10 kW (3 s) | |
| Battery dimensions W×H×D | 585 × 940 × 205 mm | |
| Battery weight / communication | 116.5 kg / RS485 | |
The 30K40 model designation does not reconcile with the battery count; SU-10k is also listed at 12 kW. Confirm the bill of materials.
| Specification | HLY-08GP-M-18K20 | HLY-10GP-M-30K40 |
|---|---|---|
| Battery operating temperature | −20–50°C; derate above 45°C | |
| Generator model / quantity | KDE6700X3 / 1 | |
| Generator rated / peak power | 5.5 / 6 kVA | |
| Generator Hz / voltage / current | 50 Hz / 203/400 V / 7.9 A | |
| Generator dimensions / weight | 720 × 492 × 650 mm / 95 kg | |
The 30K40 model designation does not reconcile with the battery count; SU-10k is also listed at 12 kW. Confirm the bill of materials.
“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.
The series and source pages are included in your brief. You can shortlist up to 15 references.
Review your project brief →Catalogue pp. 54–55 · Original model references retained. Confirm the configuration in the written technical offer.
| Specification | HLY-20GP-M-60K215 | HLY-20HQ-M-75K215 |
|---|---|---|
| PV array power | 60.5 kWp | 76.8 kWp |
| Total weight | 13.6 t | 15.2 t |
| Deployed dimensions | 91 × 3.6 × 0.8 m | 102 × 4.1 × 0.9 m |
| Folded dimensions | 3.6 × 2.0 × 2.1 m | 4.1 × 2.2 × 2.4 m |
| Maximum slope / orientation | 1% / any azimuth | |
| Deploy / fold time | 80 / 60 min | 100 / 80 min |
| Installation personnel | 4 | |
| Container type | 20GP | 20HQ |
| Container L×W×H (mm) | 6,058×2,438×2,591 | 6,058×2,438×2,896 |
| Container weight | 2.2 t | 2.5 t |
The source title states PV + storage, while its table includes a diesel generator. Confirm inclusion and quantity.
| Specification | HLY-20GP-M-60K215 | HLY-20HQ-M-75K215 |
|---|---|---|
| Rack material | Carbon-steel square tube | |
| Rack dimensions (mm) | 3,552×2,103×30 | 4,079×2,375×35 |
| Panels per rack / rack count | 3 / 42 | |
| Deployment angle | 15° | |
| Deployed rack length | 84 m | 95 m |
| Deployed rack area | 298 m² | 388 m² |
| Storage module | DH200F | |
| Battery capacity / energy | 280 Ah / 215 kWh | |
| Rated storage charge power | 100 kW | |
| Storage voltage / frequency | 672–864 V / 50 Hz | |
| Storage W×H×D (source) | 1,850 × 1,200 × 2,250 mm | |
| Storage weight / quantity | ≈3,300 kg / 1 | |
| Storage communication | RS485 | |
| Storage operating temperature | −30–50°C; derate above 45°C | |
| Diesel generator (source) | KDE16EA3 | |
| Generator rated / peak power | 13.8 / 15 kVA | |
| Generator Hz / voltage / current | 50 Hz / 203/400 V / 47.8 A | |
| Generator dimensions / weight | 930 × 660 × 910 mm / 230 kg | |
The source title states PV + storage, while its table includes a diesel generator. Confirm inclusion and quantity.
“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.
The series and source pages are included in your brief. You can shortlist up to 15 references.
Review your project brief →Catalogue pp. 56–57 · Original model references retained. Confirm the configuration in the written technical offer.
| Specification | HLY-40GP-M-160K | HLY-40HQ-M-200K |
|---|---|---|
| PV array power | 161.3 kWp | 204.9 kWp |
| Total weight | 21.5 t | 26.5 t |
| Deployed dimensions | 91 × 9.5 × 0.8 m | 102 × 10.8 × 0.9 m |
| Folded dimensions | 9.5 × 2.0 × 2.1 m | 10.8 × 2.4 × 2.2 m |
| Maximum slope / orientation | 1% / any azimuth | |
| Deploy / fold time | 160 / 100 min | 200 / 120 min |
| Installation personnel | 8 | |
| Container type | 40GP | 40HQ |
| Container L×W×H (mm) | 12,192×2,438×2,591 | 12,192×2,438×2,896 |
| Container weight | 4.2 t | 4.8 t |
The source title mentions storage but provides no battery rating. A pictured cabinet does not establish included storage.
| Specification | HLY-40GP-M-160K | HLY-40HQ-M-200K |
|---|---|---|
| Inverter model | SUN-80k | SU-100k |
| Inverter type / quantity | Grid-connected / 2 | |
| Maximum input per inverter | 104 kWp | 150 kWp |
| Rated / max AC per inverter | 80 / 88 kW | 100 / 111 kW |
| AC voltage / frequency | 3L/N/PE 220/380, 230/400 V; 50/60 Hz | |
| Maximum output current | 133.3 / 127.5 A | 166.7 / 159.4 A |
| Inverter dimensions W×H×D | 838 × 568 × 324 mm | |
| Inverter weight | 81 kg | |
| Inverter operating temperature | −25–65°C | |
| Inverter communication | RS485 / RS232 / Wi-Fi / LAN | |
| Rack material | Carbon-steel square tube | |
| Rack dimensions (mm) | 4,726×2,103×30 | 5,427×2,375×35 |
| Panels per rack / rack count | 4 / 42 | |
| Deployment angle | 15° | |
| Deployed rack length | 84 m | 95 m |
| Deployed rack area | 395 m² | 515 m² |
| Storage capacity / scope | Not supplied; confirm per project | |
The source title mentions storage but provides no battery rating. A pictured cabinet does not establish included storage.
“To confirm” and source limitations are retained. Listed ratings do not establish compatibility, local approval or a warranty for an unspecified configuration.
Datasheets and applicable certificates must match your selected model.
Home and factory paths meet in one project brief, then continue on WhatsApp.